Thyristor Dimmer & Cycle Stealing Dimmer with ZCD

These dimmers use interrupt handlers and require IRAM-safe configuration:

build_flags =
  -D CONFIG_ARDUINO_ISR_IRAM=1
  -D CONFIG_GPTIMER_ISR_HANDLER_IN_IRAM=1
  -D CONFIG_GPTIMER_CTRL_FUNC_IN_IRAM=1
  -D CONFIG_GPTIMER_ISR_IRAM_SAFE=1
  -D CONFIG_GPIO_CTRL_FUNC_IN_IRAM=1

lib_deps =
  mathieucarbou/MycilaPulseAnalyzer

Semi-period is always required

All dimmer types require Mycila::Dimmer::setSemiPeriod() to be called at startup (10000 for 50Hz, 8333 for 60Hz). For PhaseControlDimmer subclasses (Thyristor, PWM, DFRobot), it is only strictly required when enablePowerLUT(true) is set — but it is good practice to always set it. For CycleStealingDimmer, it is always required.

JSON Support

Enable JSON telemetry via toJson():

build_flags =
  -D MYCILA_JSON_SUPPORT

lib_deps =
  bblanchon/ArduinoJson

PlatformIO Development Setup

A full development configuration for working on the library:

[platformio]
lib_dir = .
src_dir = examples/Thyristor  ; or DAC, PWM, CycleStealingWithZCD, etc.

[env]
framework = arduino
board = esp32dev
build_flags =
  -D CONFIG_ARDUHAL_LOG_COLORS
  -D CORE_DEBUG_LEVEL=ARDUHAL_LOG_LEVEL_DEBUG
  -Wall -Wextra
  ; ThyristorDimmer / CycleStealingDimmer with ZCD flags
  -D CONFIG_ARDUINO_ISR_IRAM=1
  -D CONFIG_GPTIMER_ISR_HANDLER_IN_IRAM=1
  -D CONFIG_GPTIMER_CTRL_FUNC_IN_IRAM=1
  -D CONFIG_GPTIMER_ISR_IRAM_SAFE=1
  -D CONFIG_GPIO_CTRL_FUNC_IN_IRAM=1
lib_deps =
  bblanchon/ArduinoJson
  mathieucarbou/MycilaPulseAnalyzer

Troubleshooting

Thyristor Dimmer Not Working

  • Ensure the IRAM build flags listed above are set
  • Check that semi-period is configured: Mycila::Dimmer::setSemiPeriod()
  • Verify the zero-cross signal is connected and working
  • Use an oscilloscope to confirm the ZCD pulse shape

PWM Output Not Visible

  • Check GPIO pin configuration
  • Verify PWM frequency and resolution settings
  • Use an oscilloscope or an LED to test the output signal

DFRobot Module Not Responding

  • Verify I2C wiring (SDA, SCL, power, ground)
  • Check device address with an I2C scanner sketch